ECHO Complete Transthoracic – 10/3/24

 

Reason For Study: Weakness - r531                                           BSA: 2.2 m2

​

Procedure/Quality Complete 2D Echocardiogram with color and spectral Doppler was performed

(93306). The Echocardiogram was performed at bedside.

​

Interpretation Summary

The left ventricular ejection fraction is normal.

Ejection Fraction = 60-65%.

There is moderate concentric left ventricular hypertrophy.

Mild valvular aortic stenosis.

Mean gradient across aortic valve is 10mmHg.

There is no pericardial effusion.

​

Left Ventricle

The left ventricle is normal in size. There is moderate concentric left ventricular

hypertrophy. No regional wall motion abnormalities noted. Normal diastolic function for

age. Ejection Fraction = 60-65%. The left ventricular ejection fraction is normal.

​

Right Ventricle

The right ventricle is normal in size and function.

​

Atria

Normal left atrial size. Right atrial size is normal. IVC within normal limits, consistent

with normal right atrial pressure.

​

Mitral Valve

The mitral valve appears to be sclerotic. There is no mitral regurgitation noted. There is

no mitral valve stenosis.

​

Tricuspid Valve

The tricuspid valve is normal in structure and function. There is trace tricuspid

regurgitation. Right ventricular systolic pressure cannot be estimated on this examination.

​

Aortic Valve

The aortic valve appears to be sclerotic. The aortic valve is trileaflet. The V1/V2 ratio

is .48. Mean gradient across aortic valve is 10mmHg. Mild valvular aortic stenosis. No

aortic regurgitation is present.

​

Pulmonic Valve

The pulmonic valve is grossly normal. There is no pulmonic valvular regurgitation.

​

Great Vessels

The aortic root is normal in size. Proximal ascending aorta is normal in size.

Pericardial/Pleural Effusion

There is no pericardial effusion.


 

Electronically signed by: Cedric Umbridge, MD